Mga Spesipikasyon at parameter:
| Uri ng Disenyo | SiH-10KWTH-PRO | SiH-12kW-TH | SiH-15kW-TH | SiH-20kW-TH | SiH-25kW-TH | SiH-30kW-TH |
| PV(entrée) | ||||||
| Inirerekomenda max, pv input power | 20000Wp | 24000Wp | 30000Wp | 40000Wp | 50000Wp | 60000Wp |
| Max.Pv input voltage | 1000v | |||||
| Nominal na kuryente ng PV | 650V | |||||
| MPP voltas na sakop | 150V-950V | |||||
| Bilang ng MPPT /Strings kada MPPT | 3 (1/1/1) | 3(1/1/1) | 3 (2/1/1) | 3 (2/2/1) | 3(2/2/2) | |
| Makabagong kasalukuyang PV (PV1/PV2 /PV3) | 48A(16A/16A/16 A) | 64A(32A/16A/16 A) | 80A(32A/32A/16A) | 96A(32A/32A/32A) | ||
| Makabagong kasalukuyang maikling-lansangan (PV1 /PV2 /PV3) | 60A(20A/20A/20A) | 80A(40A/20A/20A) | 100A(40A/40A/20A) | 120A(40A/40A/40A) | ||
| Baterya (input/output) | ||||||
| Uri ng Baterya | Bateryang Li-ion | |||||
| Battery Voltage Range | 100V-800V | |||||
| Makabagong pag-charge at discharge current | 50A/50A* | |||||
| Makabagong pag-charge at discharge kapangyarihan | 15000W/10000W | 15000W/12000W | 30000W/15000W | 30000W/20000W | 30000W/25000W | 30000W/30000W |
| Grid (input/output) | ||||||
| Makabagong AC kapangyarihan mula sa grid | 43000W/43000VA | |||||
| Pangunahing AC output kapangyarihan | 10000VA | 12000VA | 15000VA | 20000VA | 25000VA | 30000VA |
| Maksimum na output power | 10000VA | 12000VA | 15000VA | 20000VA | 25000VA | 30000VA |
| Max. AC output na kasalukuyang | 15.2A | 18.2A | 22.8A | 30.4A | 37.9A | 45.5A |
| Nominal na boltahe ng ac | 3/N/PE,220/380V;230/400V;240/415 V | |||||
| Ang hanay ng boltahe ng AC | 270V-480V | |||||
| Rated Grid Frequency | 50Hz/60Hz | |||||
| Hanay ng mga frequency ng grid | 45Hz-55Hz/55Hz-65Hz | |||||
| THDi (Rated power) | <3% (ng rated power) | |||||
| Power factor sa Rated power / May pamantayang factor ng kapangyarihan |
>0.99 /0.8 pumapunta sa 0.8 nag-aalok | |||||
| Reserba (output) | ||||||
| Tayahering Kuryente | 3/N/PE.220V;230V;240 V | |||||
| Frequency range | 50Hz/60Hz | |||||
| THDv (Kabuuang kapangyarihan, Linear na load) | 2% | |||||
| Panahon ng pagpapatunay sa backup | <10ms | |||||
| Kinabibilangang output power habang nasa off grid mode | 10000VA | 12000VA | 15000VA | 20000VA | 25000VA | 30000VA |
| Pinakamataas na output power habang nasa off grid mode** | 15000W/15000VA 10s |
16800W/168000VA 10s |
25500W/25500VA 10s |
32000W/32000VA 10s |
36500W/36500VA 10s |
45000W/45000VA 10s |
| Makabagong kapangyarihan para sa pambansang backup bubong habang nasa on grid mode |
43000W/43000VA | |||||
| Makabagong kasalukuyang output para sa backup bubong habang nasa on grid mode |
3*63A(25°C) | |||||
| Kahusayan | ||||||
| Pinakamataas na kasiyahan / Erokopyanong kasiyahan | 98.0%/97.5 % | 98.1 %/97.6 % | 98.2%/97.8% | |||
| General Data | ||||||
| Sukat (W*H*D) | 615 mm*460 mm*245 mm | |||||
| Timbang | 34kg | 35kg | 36kg | |||
| Paraan ng Pag-mount | Mga pinto ng pag-aakyat sa dingding | |||||
| Topolohiya (Solar/baterya) | Walang transformer/Walang transformer | |||||
| Antas ng proteksyon | IP65 | |||||
| Operating ambient temperature range | -25°C~60°C,Walang pagbaba ng rating ibaba 45 °C | |||||
| Pinahihintulutang saklaw ng relatibong kahalumigmigan (Hindi nagdudulot ng pagkakondense) |
0~100% | |||||
| Paraan ng paglamig | Natural na Konbeksyon | Paglamig ng fan | ||||
| Max. operating altitude | 2000m | |||||
| Display | LED | |||||
| Communication | 2xRS485,WLAN,2 xCAN | |||||
| DI/DO | 4xDI,1xDO,DRMO | |||||
| Ang uri ng DC Connection | MC4 (PV, Max. 6mm²) Plug and play konektor (baterya, Max.10mm²) | |||||
| Ang uri ng AC connection | OT Terminals(grid /backup,Max.20mm²) | |||||
Mga katangian ng produkto:
PAKASANGKAT na pagganap.
MaX.50A disenyo para sa pagcharge at pagsasa-baterya
200% Dc input overmatching
Tatlong-hanay na asymmetrical output
sa bababa ng 100% unbalanced loads
MAINGAT NA MGA APLIKASYON.
Suporta ang multi-parallel connection
Suporta ang single-phase power output mode
100~800V malawak na battery voltage range
SUPERB OFF-GRID LOAD. Ang mga ito ay may mga mga mga mga pag-andar sa pag-andar ng mga pag-andar.
Backup para sa buong bahay
Suporta ang half-wave load at shock load
<10mS pag-switch sa labas ng grid
MAKAPAPARAPIT na disenyo.
≤ З6KG, mas madaling pag-install
Die-casting design, fanless design, low noise
Suportahan ang AFCI
Remote troubleshooting at program upgrading