Product Overview: All-in-one System single Phase High Voltage(5/6kW)
Specifications and Parameters:
| Type Designation | All-in-one sys 5kW SH | All-in-one sys 6kW SH |
| PV (input) | ||
| Max.recommended PV array power | 12000 Wp | 13000 Wp |
| Max. Pv input voltage | 600 V | |
| Min. operating PV voltage | 40 V | |
| Start-up input voltage | 50 V | |
| Rated PV input voltage | 360 V | |
| MPPT Voltage Range | 40-560 V | |
| No. of MPPT/Strings per MPPT | 2(1/1) | |
| Max. pv input current | 32 A (16 A/ 16 A) | |
| Max, current for each input connector | 40A(20 A/20 A) | |
| Max.DC short-circuit current | 20 A | |
| Battery | ||
| Battery type | Lithium-ion battery | |
| Max.charge/discharge current | 30 A/30 A | |
| Nominal voltage range | 192~512 V(64V per module) | |
| Nominal capacity range | 9.6 kWh~25.6 kwh (3.2 kwh / 50 Ah per module) | |
| Number of connectable modules | 3~8 modules | |
| Backup Output (on-Grid Mode) | ||
| Rated output power | 6000 W | |
| Rated output current | 27 A | |
| Backup Output (off-Grid Mode) | ||
| Rated output power | 5000 W/5000 VA | 6000 W/6000 VA |
| Peak output power | 8400 VA, 10S | |
| Backup switching time | <10 ms | |
| Rated voltage | 220V/230 V/240 V(+2 %) | |
| Frequency range | 50 Hz / 60 Hz (±0.5 %) | |
| Total harmonic distortion (THDv, rated power, linear load) | ≤2% | |
| Grid (input/output) | ||
| Max. AC input power from grid | 12000VA | 13000VA |
| Rated AC output power | 5000 W | 6000W |
| Max. AC output power | 5000 VA | 6000VA |
| Rated AC output current (at 230V) | 21.8 A | 26.1 A |
| Max. AC output current | 22.8 A | 27.3 A |
| Rated AC voltage | 220V/230V/240V | |
| AC voltage range | 154-276 V | |
| Rated AC frequency | 50 Hz/60 Hz | |
| Grid frequency range | 45-55 Hz/55-65 Hz | |
| Harmonic (THD) | <3 % | |
| Power factor at rated power | >0.99 | |
| Adjustable power factor | adjustable 0.8.leading to 0.8 lagging | |
| Effciency | ||
| Max.effciency/European effciency | 97.7%/97.3 % | 97.7%/97.3 % |
| Protection & Function | ||
| Surge Protection | DC type ll/Ac type ll | |
| Gird monitoring | Yes | |
| DC reverse polarity protection | Yes | |
| Battery input reverse polarity protection | Yes | |
| AC short-circuit protection | Yes | |
| Leakage current protection | Yes | |
| DC swith (PV) | Yes | |
| DC fuse (Battery) | Yes | |
| General Data | ||
| Topology (PV/Battery) | Transformerless /Transformerless | |
| Degree of protection | IP 65 | |
| Dimensions (W*H*D) | 640*1012*360 mm (With 3 Battery modules) | |
| Weight | <132 kg (With 3 Battery modules) | |
| Mounting method | Floor-standing | |
| Operating ambient temperature range | -25 °C to 60 °C | |
| Storage temperature | -20°C to 45 °C(≤1 Months)/-20°C to 25 °℃(≤6 Months) | |
| Allowable relative humidity range | 5-95 % | |
| Cooling method | Natural convection | |
| Max. operating altitude | 2000 m | |
| Display | LED indicator | |
| Communication | RS485 /CAN / WLAN | |
| DI/DO | 1*DI/1*DO/DRM | |
| DC connection type | MC4 | |
| Battery connection type | MC4 | |
| AC connection type | Screws & Fasteners | |
| STANDARD | ||
| Safety | EN/IEC62109-1/2 | |
| EMC | ENIEC61000-6-1/3 | |
| Certification | G99/EN50549/RD1699/UNE217001 | |