Specifications and Parameters:
| Type Designation | SiH-3.6kW-SL | SiH-5kW-SL | SiH-6kW-SL |
| Input (PV) | |||
| Recommend max, pv input power | 8700Wp | 10000Wp | 11000Wp |
| Max.Pv input voltage | 600V | ||
| Min. operating PV voltage | 40V | ||
| Start-up input voltage | 50V | ||
| Rated PVinput voltage | 360V | ||
| No.of independent MPPT inputs | 2 | ||
| Default No.of pv strings per MPPT | 1 | ||
| Max. PV input current | 16A | ||
| Max,DC short-circuit current | 20A | ||
| Input/output(Ac) | |||
| Max.AC input power from grid | 8700VA | 10000VA | 11000 VA |
| Rated Ac output power | 3680W | 5000W | 6000W |
| Max. AC output power | 3680VA | 5000VA | 6000VA |
| Max. AC output current | 16.7A | 22.8A | 27.3A |
| Rated AC voltage | 220V/230V/240V | ||
| AC voltage range | 154V~276V | ||
| Rated grid frequency | 50HZ/60HZ | ||
| Grid freguency range | 45~55Hz/55~65Hz | ||
| Harmonic(THD) | <3% | ||
| Power factor at rated power | >0.99 | ||
| Adjustable power factor | adj.0.8.overexcited/leading to 0.8 underexcited/lagging | ||
| Grid Type | Single phase | ||
| Battery Data | |||
| Battery Type | Li-ion battery | ||
| Battery voltage | 40-59V | ||
| Max. charge current | 100A | ||
| Max. discharge current | 100A | ||
| Max.charge power | 5000W | ||
| Max. discharge power | 5000W | ||
| General Data | |||
| Dimensions (W*H*D) | 600*365*194mm | ||
| Weight | ≤23.5kg | ||
| Mounting method | Wall-mounting bracket | ||
| Topology (Solar/Battery) | Transformerless | ||
| Degree of protection | IP65 | ||
| Operating ambient temperature range | -25°C~60°C | ||
| Allowable relative humidity range | 0~100% | ||
| Cooling method | Natural convection | ||
| Max. operating altitude | 4000m | ||
| Display | LED indicator | ||
| Communication | RS485/CAN/WLAN | ||
| DI/DO | DIx1/DOx1/DRM | ||
| DC connection type | MC4 | ||
| Battery connection type | MC4 | ||
| AC connection type | Screws & Fasteners | ||
| Backup Data (on-grid) | |||
| Rated output power for backup load | 6000 W | ||
| Rated output current for backup load | 27A | ||
| Backup Data (off-grid model) | |||
| Rated voltage | 220V/230V/240V(+2%) | ||
| Frequency range | 50Hz/60Hz(+0.5%) | ||
| Total output THDV for liner load | ≤2% | ||
| Switch time to emergency mode | ≤10 ms | ||
| Rated output power | 3000 W/3000 VA | 5000W/5000VA | 5000W/6000VA |
| Peak output power | 8400 VA,10S | ||
Product Features:
OUTSTANDING PERFORMANCE.
40~59V wide battery voltage range
MaX.5kW charging and discharging
240% Dc input oversizing
50V extra low start-up voltager
FLEXIBLE APPLICATIONS.
Support multi-parallel connection
Equipped with Dl\Do port
MaX.16A DC input
SUPERB OFF-GRID LOAD.
Whole-home backup
Support half-wave load and shock load
<10mS off-grid switching
FRIENDLY DESIGN.
Die-casting design,fanless design, low noise
Support AFCI
Remote troubleshooting and program upgrading
INTELLIGENT MULTIPLE OPERATING MODES AVAILABLE.
Self-generated, zero power feeder, Vpp, battery-free, battery-free & gridless